Energy Storage Batteries for Data Center Backup

 


Energy storage batteries for data centers serve as the first line of defense against power outages, ensuring uninterrupted operation of servers, cooling systems, and critical infrastructure. These batteries must deliver near-instantaneous power (within milliseconds) for short durations (1030 minutes), bridging the gap until diesel generators start. Data center operators prioritize reliability, fast response, and low maintenance, as even brief outages can cause data loss, service disruptions, and multimillion-dollar losses.  

VRLA (valve-regulated lead-acid) batteries have long been the standard for data center backup due to their proven reliability and quick discharge capability. AGM (absorbed glass mat) variants are preferred for their sealed design, preventing acid leakage and allowing installation in raised floors or close to equipment. A typical data center uses 48V DC battery strings arranged in parallel, with capacities ranging from 50 kWh to 1 MWh per UPS (uninterruptible power supply) system. Their high power density (up to 300 W/kg) enables rapid energy delivery during outages, while slow self-discharge (12% per month) ensures readiness during standby.  

Lithium-ion batteries are increasingly adopted in modern data centers for their higher energy density and longer lifespan. Lithium nickel manganese cobalt (NMC) or lithium iron phosphate (LFP) cells offer 23 times the cycle life of lead-acid (2,000+ cycles vs. 300500), reducing replacement costs over a data centers 20-year lifespan. Their compact sizeup to 50% smaller than equivalent lead-acid systemssaves valuable floor space in high-cost data centers. Smart BMS features enable real-time monitoring of each cells health, predicting failures before they occur, and integrating with data center management systems for proactive maintenance.  

Safety is paramount in data center batteries. They must be housed in fire-retardant enclosures with thermal runaway detection, and some systems use nitrogen inerting to suppress combustion risks. Energy efficiency is also critical, as standby power consumption (quiescent loss) must be minimal to reduce operational costs. With the rise of hyperscale data centers (consuming hundreds of MW), battery technologies are evolving to support higher capacities while maintaining reliability, with innovations like modular battery racks, AI-driven health monitoring, and sustainable recycling programs to address e-waste concerns.  

 

Back to list
Our website uses cookies and thereby collects information about your visit to improve our website, show you social media content and relevant advertisements. Please see our cookies page for further details or agree by clicking the 'Accept' button.

Cookie settings

Below you can choose which kind of cookies you allow on this website. Click on the "Save cookie settings" button to apply your choice.

FunctionalOur website uses functional cookies. These cookies are necessary to let our website work.

AnalyticalOur website uses analytical cookies to make it possible to analyze our website and optimize for the purpose of a.o. the usability.

AdvertisingOur website places advertising cookies to show you 3rd party advertisements based on your interests. These cookies may track your personal data.

OtherOur website places 3rd party cookies from other 3rd party services which aren't Analytical, Social media or Advertising.